Battery Backup for a Router and NAS
UPS Picks That Fit
Choose a battery backup for your router and NAS by load, outlets and shutdown support. Compare APC and CyberPower, check runtime, and wire every needed box.
By thisPING EditorialUpdated November 2, 20268 min read2 picks
Our recommendation: APC Back-UPS BE600M1
Best for a router and modem
Limit: A surge-only socket does not supply outage power.
On this page · Our picks at a glance
Our picks at a glance
- 1
Choose for: Best for a router and modem
Limit: A surge-only socket does not supply outage power.
- 2
Choose for: Best for a NAS and small homelab
Limit: CyberPower says AVR corrects minor power fluctuations without using the battery and explicitly lists active-PFC power-supply compatibility.
For a battery backup for a router and modem, choose the APC Back-UPS BE600M1: its five battery-backed outlets suit a small network that needs to stay powered. For a NAS and small homelab, choose the CyberPower CP1500PFCLCD, subject to NAS compatibility: sine-wave output, a USB data port and greater output capacity make it our preferred starting point. Choose runtime from your measured load, then configure the NAS to stop safely before the battery runs out.
Quick picks: continuity or NAS protection?
These are US AC models. APC's official US product page and CyberPower's current product page provide the comparison below.
APC BE600M1
- Choose it for
- Router, modem or ONT and a modest network
- Output limits
- 600 VA / 330 W
- Battery-backed / surge-only outlets
- 5 / 2
All specifications
- Battery waveform
- Stepped approximation to a sine wave
- Shutdown connection
- Separate USB data port, documented in APC's manual
CyberPower CP1500PFCLCD
- Choose it for
- NAS, network equipment and a small homelab
- Output limits
- 1500 VA / 1000 W
- Battery-backed / surge-only outlets
- 6 / 6, per current page and datasheet; manual conflict below
All specifications
- Battery waveform
- Sine wave
- Shutdown connection
- HID-compliant USB; optional RMCARD205 for network management
Full comparison table
Swipe to compare. Row labels stay visible.
| UPS | Choose it for | Output limits | Battery-backed / surge-only outlets | Battery waveform | Shutdown connection |
|---|---|---|---|---|---|
| APC BE600M1 | Router, modem or ONT and a modest network | 600 VA / 330 W | 5 / 2 | Stepped approximation to a sine wave | Separate USB data port, documented in APC's manual |
| CyberPower CP1500PFCLCD | NAS, network equipment and a small homelab | 1500 VA / 1000 W | 6 / 6, per current page and datasheet; manual conflict below | Sine wave | HID-compliant USB; optional RMCARD205 for network management |
| UPS | Choose it for | Output limits | Battery-backed / surge-only outlets | Battery waveform | Shutdown connection |
|---|---|---|---|---|---|
| APC BE600M1 | Router, modem or ONT and a modest network | 600 VA / 330 W | 5 / 2 | Stepped approximation to a sine wave | Separate USB data port, documented in APC's manual |
| CyberPower CP1500PFCLCD | NAS, network equipment and a small homelab | 1500 VA / 1000 W | 6 / 6, per current page and datasheet; manual conflict below | Sine wave | HID-compliant USB; optional RMCARD205 for network management |
For router continuity, prioritize the required runtime and usable outlet spacing. For a NAS, add a verified shutdown data link and enough time to stop services. Output watts tell you whether the UPS can carry the load; they do not specify how long it will run.
Best for a router and modem: APC Back-UPS BE600M1
<!-- Product card awaits the owner's ASIN confirmation; record: products/apc-be600m1.json. -->The BE600M1 has seven outlets: five battery-backed and two surge-only, with 600 VA / 330 W limits. APC lists a standby topology, stepped sine-wave approximation, floor/wall mounting and a user-replaceable APCRBC154 battery. It is our straightforward choice when the job is keeping essential network boxes powered.
Put every essential adapter on a battery-backed outlet. A surge-only socket does not supply outage power. Check the physical fit of your power bricks before counting all five backed outlets as usable.
USB and model trap: the shared APC manual identifies a USB charger and a separate data port on the BE600M1. Its similarly named BN650M1 lacks the data port; the manual distinguishes that model from the BN650M1-CA. Buy by the complete model code, especially if you might add NAS shutdown later.
Choose the CyberPower instead when sine-wave output or its higher capacity is a requirement. APC's manual acknowledges that some connected equipment may not accept the BE600M1's stepped waveform. Neither its USB data port nor its capacity alone establishes compatibility with your NAS.
Check the BE600M1 configuration at APC / Schneider Electric.
Best for a NAS and small homelab: CyberPower CP1500PFCLCD
<!-- Product card awaits the owner's ASIN confirmation; record: products/cyberpower-cp1500pfclcd.json. -->The currently listed US version supplies 1500 VA / 1000 W, sine-wave battery output and automatic voltage regulation (AVR). CyberPower says AVR corrects minor power fluctuations without using the battery and explicitly lists active-PFC power-supply compatibility. Its HID-compliant USB data port makes it a candidate for supported NAS shutdown; check your NAS maker's compatibility information before ordering.
Confirm the hardware: the current page and datasheet specify 12 outlets, six backed and six surge-only, plus Type-A and Type-C charging sockets. The linked manual calls its specification-table model CP1500PFCLCDa and says five UPS outlets, although its operation text says six. Confirm the rear-panel layout of the supplied unit; the documentation does not settle that discrepancy.
Plan space for a 24.9 lb mini-tower with two widely spaced outlets; check adapter fit before buying. Replacement batteries also depend on the serial-number prefix, according to CyberPower's page. Its RJ45 surge-protection path is specified for 10/100/1000 Ethernet; for multi-gig equipment, keep Ethernet directly connected between network devices. Those surge-protection jacks are separate from optional network management.
Check the exact CP1500PFCLCD at CyberPower.
Inventory the boxes, then draw both cable paths
Trace the connection from the modem or ONT to the router, then through any required switch to the NAS and access point. Hitron's CODA56 manual, for example, connects the modem by Ethernet to the router's WAN port and powers each separately. Include a remote mesh node if you need coverage there during the outage; a UPS beside the gateway is not a power source for another room.
For PoE, include the switch or injector that supplies the access point or camera. Netgear's GS308EPP page explicitly describes powering those devices through Ethernet. When measuring the switch's complete AC input with its PoE devices active, count that reading once.
AC input
Grounded wall outlet → UPS, following its manual.
AC output branches
Battery-backed outlets → each original AC adapter → modem or ONT, router, required switch or access point, and NAS. These are parallel power connections.
Shutdown signal
UPS data port → NAS USB port. For network UPS clients, keep the intervening switch powered too.
Synology specifically requires the switch or hub carrying network UPS messages to share UPS power. Keep a remote ONT's location in the inventory: it needs backup where its own power supply is installed. Our modem vs router guide helps identify the boxes; NAS choices for home covers the storage side.
Fill in a load worksheet before choosing runtime
Record the original PSU's output voltage, current, connector and polarity; for USB-C, check the supported power profiles. Keep the original AC adapters on the UPS. Do not assume a phone-charging socket or an unverified mini DC UPS can replace them.
The existing eero Pro 7, Hitron CODA56 and Synology DS225+ are useful examples of why labels and consumption need separate columns:
Modem or ONT; CODA56 example
- Manufacturer's reference
- Adapter output: 12 V DC, 2 A
- Your measured AC watts
- Fill in
- Battery-backed socket / fit
- Check
Router; eero Pro 7 example
- Manufacturer's reference
- 27 W PSU; eero reports 7 W typical
- Your measured AC watts
- Fill in
- Battery-backed socket / fit
- Check
Required switch, PoE devices and remote nodes
- Manufacturer's reference
- Record your exact devices and active PoE load
- Your measured AC watts
- Fill in
- Battery-backed socket / fit
- Check
NAS; DS225+ example
- Manufacturer's reference
- 60 W adapter; Synology lists 16.98 W in access, 6.08 W in HDD hibernation
- Your measured AC watts
- Fill in during activity
- Battery-backed socket / fit
- Check
Attached storage and other essential equipment
- Manufacturer's reference
- Add each separately powered device
- Your measured AC watts
- Fill in
- Battery-backed socket / fit
- Check
Full comparison table
Swipe to compare. Row labels stay visible.
| Powered box | Manufacturer's reference | Your measured AC watts | Battery-backed socket / fit |
|---|---|---|---|
| Modem or ONT; CODA56 example | Adapter output: 12 V DC, 2 A | Fill in | Check |
| Router; eero Pro 7 example | 27 W PSU; eero reports 7 W typical | Fill in | Check |
| Required switch, PoE devices and remote nodes | Record your exact devices and active PoE load | Fill in | Check |
| NAS; DS225+ example | 60 W adapter; Synology lists 16.98 W in access, 6.08 W in HDD hibernation | Fill in during activity | Check |
| Attached storage and other essential equipment | Add each separately powered device | Fill in | Check |
| Powered box | Manufacturer's reference | Your measured AC watts | Battery-backed socket / fit |
|---|---|---|---|
| Modem or ONT; CODA56 example | Adapter output: 12 V DC, 2 A | Fill in | Check |
| Router; eero Pro 7 example | 27 W PSU; eero reports 7 W typical | Fill in | Check |
| Required switch, PoE devices and remote nodes | Record your exact devices and active PoE load | Fill in | Check |
| NAS; DS225+ example | 60 W adapter; Synology lists 16.98 W in access, 6.08 W in HDD hibernation | Fill in during activity | Check |
| Attached storage and other essential equipment | Add each separately powered device | Fill in | Check |
References: Hitron specifications, eero PSU, eero consumption and Synology specifications. These are manufacturer figures, not readings of your installation.
Add your measured AC readings with the equipment doing its normal work, and check startup demand as well. A PSU's rated output is not an actual AC consumption measurement. Stay within both watt and VA limits: Schneider Electric explains that neither may be exceeded. Leave headroom for changing loads and additions; CyberPower's manual recommends keeping load below 80% of rated capacity.
Read the exact manufacturer's runtime curve
Open the CP1500PFCLCD's Runtime tab or CyberPower runtime calculator and select that exact model. Its current curve gives approximately 100 minutes at 50 watts, 66 minutes at 100 W and 30.8 minutes at 200 W. CyberPower qualifies the curve as based on new, fully charged batteries under normal conditions; age, charge and environment change the result.
Source: CyberPower manufacturer curve data; approximate, new fully charged batteries
Use your complete backed-up load on the curve. Do not extrapolate those points into promised hours for a smaller router load, or transfer them to another UPS. APC's BE600M1 page has a load-specific runtime widget with a 33–330 W input range; seek manufacturer guidance if your load falls outside the available curve.
For a NAS, the required runtime must cover your chosen standby delay, the time it takes to stop safely, and reserve. For router continuity, choose the outage duration you want to cover and verify it at the actual load. Shutting down the NAS changes the shared UPS load, so a constant-load curve cannot promise an exact combined runtime afterward.
Set up NAS shutdown without cutting off the router
In Synology DSM, connect the UPS data cable, open Control Panel → Hardware & Power → UPS, enable UPS support and select USB UPS. Check Device Information, set the time before Standby Mode, and apply. Standby Mode stops services and unmounts volumes; file serving does not continue in that state.
Synology recommends consulting its compatibility list before purchasing peripherals. A HID port establishes a data capability, not approval for every NAS, operating system or hardware revision. Confirm detection, the battery event and the complete shutdown sequence on your own combination before leaving it unattended.
Follow the UPS manual's battery-connection and initial-charging instructions. Run Synology's documented outage simulation and check recovery when utility power returns; review Restart automatically after a power failure if you want the NAS to restart automatically.
What happens if the ISP loses power?
A powered router cannot repair an upstream outage. Comcast says its network requires commercial power. Verizon says its Battery Storage Unit supports voice only, excluding internet and TV. Back up the ONT's normal supply rather than assuming its voice battery covers broadband.
Before ordering, complete this final check:
- Yes: Exact US model, regional plug and battery-backed outlet layout confirmed
- Yes: Every essential powered box and adapter included; both output limits leave headroom
- Yes: Manufacturer curve checked at your load and desired runtime
- Partly: NAS shutdown depends on exact-device support, detection and configured behavior
- No: Surge-only outlets, USB charging sockets and an ISP voice battery do not substitute for the required backup and data paths
How we choose
This is a manufacturer-documentation comparison, checked November 2, 2026. No physical or runtime tests were performed for this guide. We prioritize network power paths, usable backed outlets, load-specific curves, waveform requirements and documented shutdown interfaces. The CP1500PFCLCD outlet discrepancy remains explicit; neither pick carries a blanket NAS-compatibility claim. See How we choose for our editorial method.
Verdict
Get the BE600M1 for a small router/modem setup after checking its curve and adapter fit. Choose the CP1500PFCLCD for a NAS or small homelab needing its sine-wave output and higher capacity, after confirming the supplied hardware and shutdown support. The purchase is complete only when every necessary box has backed power and the NAS shutdown policy preserves the network runtime you want.
thisPING is reader-supported: when you buy through our links, we may earn a commission at no extra cost to you. As an Amazon Associate, thisPING earns from qualifying purchases.
Frequently asked questions
How long will a battery backup run my router?
Use the exact UPS model's runtime curve at the total measured load, including the modem or ONT and any required switch. CyberPower's CP1500PFCLCD curve gives approximately 100 minutes at 50 watts and 66 minutes at 100 W. Those are manufacturer reference values for new, fully charged batteries. They are not a router-specific guarantee; battery age, charge and environment change runtime.
Can a USB charging port shut down a NAS?
A charging socket supplies power; shutdown needs a supported data connection and NAS configuration. The BE600M1 manual identifies a separate USB data port, and CyberPower lists a HID-compliant USB port on the CP1500PFCLCD. For Synology, connect that data link, enable USB UPS support in DSM, and confirm Device Information. Verify compatibility for your exact NAS and UPS before relying on unattended shutdown.
Does a NAS need a pure sine-wave UPS?
Follow the NAS and power-supply makers' requirements. We prefer the CP1500PFCLCD for a NAS or small homelab because CyberPower explicitly supports active-PFC supplies and provides sine-wave battery output. The BE600M1 uses a stepped approximation, and APC's manual acknowledges that some equipment may not accept it. That does not establish that every NAS needs sine wave; verify your particular combination.
Will a UPS keep my internet working during a power outage?
It can keep your own powered equipment running for its available battery runtime. Your modem or ONT, router and any required network devices all need power, and your provider's network must remain available. Comcast says its network requires commercial power. Verizon also warns that its Battery Storage Unit backs up voice service only, so that unit is not an internet backup.
Best for a router and modem
APC Back-UPS BE600M1